• Sourcing Solutions
  • Services & Membership
  • Help & Community

Quick Details

  • Type: Laser
  • Laser Type: CO2 Laser
  • Q-Switch: No
  • Style: Stationary
  • Certification: CE IEC
  • Place of Origin: Beijing, China (Mainland)
  • Brand Name: Oriental Wison
  • Model Number: OW-G1
  • Feature: Acne Treatment, Blood Vessels Removal, Face Lift, Pigment Removal, Skin Rejuvenation, Wrinkle Remover, scars removal, stretch marks removal
  • Laser type: fractional co2 laser
  • Wavelength: 10600nm
  • Output power: ≤30W (optional)
  • Area of Focal spot: 0.05mm2
  • Wavelength of the target: 635 nm
  • Conduct system: Seven-joints laser articulated arm
  • Optical system: 7 articulated arms
  • Laser indicator: 650nm ruby laser
  • Power of Target optical: ≤ 5mw
  • Warranty: 3 years

Packaging & Delivery

Packaging Details Aluminous box plus thick sponge
Delivery Time 3-5 working days after payment
Why Choose Us
Product Description

2017 Newest technology skin resurfacing acne scar treatment CO2 fractional laser beauty device

CO2 fractional laser machine

Laser type
fractional CO2 laser
Wavelength
10600nm
Machine power
50W
Output power
≤30W (optional)
Operating voltage
AC 220V ± 10%, 50Hz
Area of Focal spot
0.05mm2
Wavelength of the target
635 nm
Conduct system
Seven-joints laser articulated arm
Optical system
7 articulated arms
Laser indicator
650nm ruby laser
Power of Target optical
≤ 5mw
Diameter of Focal spot
0.25mm
Area of Focal spot
0.05mm2
Graphic area
≤ 20mm × 20mm
Cooling system
Wind cooling system
Warranty
3 years

Function

1. Skin tightening , fractional skin resurfacing , Skin renewing, wrinkle removal, whitening , pore minimization.
2. Acne scar removal, scars and surgery scars, dermabrasion, Remove intractable chloasmas and pigmentation, etc.
3. CO2 laser cutting in aesthetic surgery: mainly used for cutting on blepharoplasty , skin tags and ingrown nails , compound nevus and intra dermal nevus ect.

1. CO2 Fractional laser is the most advanced conceptual fractional CO2 skin peeling laser system with a wavelength of 10600nm. In addition to its fine skin-peeling effect, it can effectively penetrate the laser beam into the dermis.

2. Laser machine has 2 kinds of operating system; one is fractional CO2 laser for scars removal, skin rejuvenation, stretch marks removal.

3. And another system is for vaginal rejuvenation. It has 2 probes. On the probe there is 2940 lens, so it is mixture of 10600nm & 2940nm light. This system only has 2 shapes: round & square.

1. USA coherent laser device
2. 10600 nm wavelength
3. 50 Watts max power
4. Ellipse scan, rectangle scan, triangle scan
5. 650nm ruby laser indicator
6. Wind cooling system
7. Compared with traditional fractional CO2 laser, this model has steady energy output and dramatic treatment results. What's more, you do not need to change the CO2 tube at all.

Scanner treatment
Power(w)0-30w
Duration(ms)0.1-10ms
Interval(ms)1-5000ms
Distance(mm)0.1-2.6mm
Scanning mode
Time(th)1-20th
Point energy(mj)
fraction of coverage(%)
Wrinkle removal
12w-28w
0.8-1.2ms
1ms
0.5-1.0mm
Sequential or random mode
1
9.6mj-33.6mj
25%-50%
A second scan is completed rest for 10 to 20 days, three times as a course of treatment. Usually 1-2 treatments wrinkle can be significantly improved.
Scar removal
12w-28w
0.8-1.2ms
1ms
0.5-1.0mm
Sequential or random mode
1
9.6mj-33.6mj
25%-50%
A second scan is  completed rest for 10 to 20 days, three times as a course of treatment. Usually 1-2 treatments to basically eliminate the scars.
Vascular removal
10w-25w
0.8-1.2ms
1ms
0.5-1.0mm
Sequential or random mode
1
8mj-30mj
25%-50%
A second scan is completed rest for 10 to 20 days, three times as a course of treatment. Usually 1-2 treatments may be substantially removed.
Large pores
10w-25w
0.8-1.2ms
1ms
0.5-1.0mm
Sequential or random mode
1
8mj-30mj
25%-50%
A second scan is completed rest for 10 to 20 days, three times as a course of treatment. Usually 1-2 treatments to improve the appearance of the skin significantly.
Mole removal
15w-30w
0.8-1.2ms
1ms
0.5-1.0mm
Sequential or random mode
1
12mj-36mj
25%-50%
A second scan is completed rest for 10 to 20 days, three times as a course of treatment. Usually 1-2 treatments mole son can be removed.
Contact Us
Hot Sale

  CO2 LASER                                     DIODE LASER                                    PICO LASER

          OPT                                             ND YAG LASER                                     DIODE LASER

Our Company
Packing & Express
Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview

Transactions

Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date
Email to this supplier
Trade Assurance
China (Mainland) | Trading Company
Transaction Level:
Supplier Assessments:
25 Transactions 40,000+
The supplier’s transactions conduted via Alibaba.com in the past 6 months.
The supplier supports Trade Assurance – A free service that protects your orders from payment to delivery.
Supplier's Trade Assurance Limit: US $48,000